3 Electrical Measuring Devices
3.1 General Requirements
3.1.1 The electrical measuring devices shall be configured to correctly show the electrical operating parameters and insulation of power devices.
3.1.2 Electrical measuring devices should incorporate measuring components of computer supervisory systems,general electrical measuring meters and measuring components of other integrated devices.
3.1.3 Electrical measuring devices may measure by using instruments directly or indirectly through primary instruments or secondary instruments.
3.1.4 It is required that the accuracy of electrical measuring devices shall not be lower than the values specified in Table 3.1.4.
Table 3.1.4 Required Accuracy of Electrical Measuring Devices

3.1.5 The total accuracy of AC circuit indicating instruments shall not be lower than class 2.5,and the total accuracy of DC circuit indicating instruments shall not be lower than class 1.5.The accuracy of instruments connected to the secondary side of electrical measuring transducers shall not be lower than class 1.0.The accuracy of current and voltage transformers,accessories and fittings for electrical measuring devices shall not be lower than the values specified in Table 3.1.5.
Table 3.1.5 Required Accuracy(Class)of Current and Voltage Transformers,Accessories and Fittings of Electrical Measuring Devices

3.1.6 The measuring range of pointer-type meters should be selected such that the rated value of power equipment is at 2/3 of the full scale.Overload meters should be used for power equipment and circuits that may be overloaded.
3.1.7 The electrical measurement of several power equipment and circuits of the same type may be performed in a selective manner.
3.1.8 In case of secondary measurement made via transducers,the full scale value of secondary measuring meters shall match with the calibration value of transducers and can be calculated as per Appendix A and B to this code.
3.1.9 For bidirectional-current DC circuits and bidirectional-power AC circuits,ammeters and wattmeters/varmeters with bidirectional scales shall be used.Polar meters shall be employed for polar DC current and voltage circuits.
3.1.10 Ammeters with overload scales should be used for heavy-duty start motors and power equipment and circuits potentially subjected to short-time impulse current.
3.1.11 In power plants and substations deployed with remote telemetry and computer supervisory systems(DC sampling applied),secondary measuring meters,computer and remote telemetry systems should share one set of transducers.
3.1.12 The upper limit of meters in excitation circuits shall not be lower than 1.3 times the value for rated conditions,and the total error of meters shall not exceed 1.5%.
3.1.13 The measuring range of meters for reactive power compensators shall be selected such that it can accommodate the maximum current and voltage that may occur at the devices.The current measuring device for shunt capacitor banks shall be designed assuming that the continuous current flowing through the shunt capacitor bank is 1.35 times the rated current.
3.1.14 The measuring components in both computer supervisory systems and integrated devices may substitute the corresponding general electrical measuring meters provided that their accuracies are acceptable.
3.1.15 The electrical measuring devices adopted in direct instrument measurements shall meet the requirements on dynamic and thermal stability of primary circuits.
- GB/T 50537-2017 油氣田工程測量標準
- GB 51180-2016 煤礦采空區建(構)筑物地基處理技術規范
- GB50588-2017水泥工廠余熱發電設計標準(英文版)
- DL/T 5491-2014 電力工程交流不間斷電源系統設計技術規程
- DL/T 5502-2015 串補站初步設計文件內容深度規定
- GB50548-2010330kV-750kV架空輸電線路勘測規范(英文版)
- GB 51162-2016 重型結構和設備整體提升技術規范
- GB 51156-2015 液化天然氣接收站工程設計規范
- 電氣工程師手冊(第4版)
- DL/T 5334-2016 電力工程勘測安全規程
- GB/T 50312-2016 綜合布線系統工程驗收規范
- GB 50311-2016 綜合布線系統工程設計規范
- GB50397-2007冶金電氣設備工程安裝驗收規范(英文版)
- GB 51151-2016 城市軌道交通公共安全防范系統工程技術規范
- 沖壓加工技能培訓與操作實踐